125kW/261kWh liquid-cooled outdoor integrated energy storage system with 125kW rated AC output for C&I outdoor applications.
Battery PACK Parameters
| Project | Unit | Parameter |
|---|---|---|
| Cell type | - | LFP314Ah |
| Combination | - | 1P52S |
| Rated voltage | V | 166.4 |
| Rated energy | kWh | 52.25 |
| C-rate | C | ≤0.5 |
Battery Cluster Parameters
| Project | Unit | Parameter |
|---|---|---|
| Series number | - | 260 |
| Voltage range | V | 650–949 |
| Rated voltage | V | 832 |
| Rated energy | kWh | 261 |
| C-rate | C | ≤0.5 |
AC System Parameters
| Project | Unit | Parameter |
|---|---|---|
| Rated output power | kW | 125 |
| Maximum output power | kW | 137 |
| Wiring method | - | 3P4W |
| Rated voltage | V | 380 |
| Frequency | - | 50Hz/60Hz±2.5Hz |
General Parameters
| Project | Unit | Parameter |
|---|---|---|
| Dimensions (W×D×H) | mm | 1000×1300×2500 |
| Weight | kg | 2600 |
| Operating temperature | °C | -20 – +55 |
| Relative humidity | %RH | 0–90 |
| Working altitude | m | ≤3000 |
| Cooling method | - | Liquid cooling |
| IP protection | - | Pack:IP65, System:IP54 |
| Communication | - | Wireless 4G / Ethernet |
| Outlet mode | - | Bottom in, bottom out |
| Fire protection | - | Perfluorohexane |
| Certification | - | CE, ROHS, UN38.3, IEC/EN 62619, IEC/EN 62368-1, IEC 60730-1, IEC/EN 61000 |